Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Aust Endod J ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509781

RESUMO

This study aimed to evaluate the interface of universal adhesive (UA) with bulk-fill resin (BF) and dentin, after endodontic irrigation. The pulp chamber of 96 molars was irrigated with chlorhexidine 2% (CHX) or sodium hypochlorite 5.25% (NaOCl) and restored according to three restorative protocols. Microtensile bond strength (µTBS) and nanoleakage tests were performed after 24 h of thermocycling. Kruskal Wallis, Mann-Whitney and Wilcoxon were performed (p < 0.05). Comparing restorative systems, a difference was found only when irrigated with CHX after 24 h. CHX provided higher µTBS than NaOCl after 24 h for two restorative protocols; after thermocycling, NaOCl provided the greatest µTBS than CHX for one group. Decreased µTBS was observed for all restorative systems when CHX was used after thermocycling. NaOCl demonstrated the highest nanoleakage. The composition of UA influenced the immediate adhesion and sealing to BF when CHX was used; ageing has a deteriorating effect on adhesion and sealing for all restorative systems.

2.
Braz Dent J ; 34(6): 67-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38133093

RESUMO

This study aimed to evaluate the influence of dental adhesive color on the chromatic stability and fluorescence intensity of composite resin restorations of different thicknesses. Ninety bovine enamel samples were obtained and restored with resin composite varying thicknesses of restorative material and enamel (1.0 mm enamel and 1.0 mm composite; 1.5 mm enamel and 0.5 mm composite; 0.5 mm enamel and 1.5 mm composite). The restorations were made of composite resin (Opallis E-bleach H) using different types of dental adhesives: Ambar, Ambar APS, and Single Bond Universal (n=10). The samples were subjected to color measurement tests in a spectrophotometer using CIEDE2000 and fluorescence intensity measurements before and after aging in a red wine coloring solution. Data were subjected to analysis of variance (ANOVA) and Tukey's test (α = 0.05). There were no statistically significant changes in color stability or fluorescence intensity for restorations made of different materials or thicknesses (p>0.05). Single Bond Universal showed greater color stability at 0.5 mm thickness (ΔE00 = 4.4 ± 1.6) compared to other thicknesses of the same material (p=0.003), as well as a greater difference in fluorescence intensity after aging at 1.5 mm thickness (-414.9 ± 103.8) compared to other materials (p=0.0002). Overall, it was concluded that the different adhesive systems did not influence the color stability and fluorescence of restorations of different thicknesses.


Assuntos
Cimentos Dentários , Cimentos de Resina , Animais , Bovinos , Cimentos Dentários/química , Cimentos de Resina/química , Resinas Compostas/química , Cor , Teste de Materiais
3.
Braz. dent. j ; 34(6): 67-74, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528033

RESUMO

Abstract This study aimed to evaluate the influence of dental adhesive color on the chromatic stability and fluorescence intensity of composite resin restorations of different thicknesses. Ninety bovine enamel samples were obtained and restored with resin composite varying thicknesses of restorative material and enamel (1.0 mm enamel and 1.0 mm composite; 1.5 mm enamel and 0.5 mm composite; 0.5 mm enamel and 1.5 mm composite). The restorations were made of composite resin (Opallis E-bleach H) using different types of dental adhesives: Ambar, Ambar APS, and Single Bond Universal (n=10). The samples were subjected to color measurement tests in a spectrophotometer using CIEDE2000 and fluorescence intensity measurements before and after aging in a red wine coloring solution. Data were subjected to analysis of variance (ANOVA) and Tukey's test (α = 0.05). There were no statistically significant changes in color stability or fluorescence intensity for restorations made of different materials or thicknesses (p>0.05). Single Bond Universal showed greater color stability at 0.5 mm thickness (ΔE00 = 4.4 ± 1.6) compared to other thicknesses of the same material (p=0.003), as well as a greater difference in fluorescence intensity after aging at 1.5 mm thickness (-414.9 ± 103.8) compared to other materials (p=0.0002). Overall, it was concluded that the different adhesive systems did not influence the color stability and fluorescence of restorations of different thicknesses.


Resumo O objetivo deste estudo foi avaliar a influência da cor do adesivo dental na estabilidade cromática e intensidade de fluorescência das restaurações de resina composta de diferentes espessuras. Foram obtidos noventa amostras de esmalte bovino que foram restaurados com resina composta, variando a espessura do material restaurador e do esmalte (1,0 mm de esmalte e 1,0 mm de compósito; 1,5 mm de esmalte e 0,5 mm de compósito; 0,5 mm de esmalte e 1,5 mm de compósito). As restaurações foram feitas de resina composta (Opallis E-bleach H) utilizando diferentes tipos de adesivos odontológicos: Ambar, Ambar APS, e Single Bond Universal (n=10). As amostras foram submetidas a testes de medição de cor em um espectrofotômetro usando CIEDE2000 e medições de intensidade de fluorescência antes e depois do envelhecimento em uma solução de coloração de vinho tinto. Os dados foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (α = 0,05). Não houve mudanças estatisticamente significativas na estabilidade da cor ou intensidade de fluorescência para restaurações feitas de diferentes materiais ou espessuras (p>0,05). O Single Bond Universal mostrou maior estabilidade de cor a 0,5 mm de espessura (ΔE00 = 4,4 ± 1,6) em comparação com outras espessuras do mesmo material (p=0,03), bem como uma maior diferença na intensidade de fluorescência após o envelhecimento a 1,5 mm de espessura (-414,9 ± 103,8) em comparação com outros materiais (p=0,0002). Em geral, concluiu-se que os diferentes sistemas adesivos não influenciaram a estabilidade de cor e a intensidade de fluorescência das restaurações de diferentes espessuras.

4.
J Dent ; 127: 104348, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36280006

RESUMO

OBJECTIVES: This in vitro study aimed to evaluate the effect of different times and concentrations of hydrofluoric acid etching on the surface of indirect restorative materials obtained from blocks used in CAD-CAM technology. METHODS: Specimens (4 mm × 4 mm × 0.8 mm) were obtained for each indirect restorative material: zirconia-reinforced lithium monosilicate ceramic (Celtra Duo), nanoceramic resin (Lava Ultimate), and polymer-infiltrated ceramic network material (Vita Enamic). The materials were submitted to etching with 5% or 10% hydrofluoric acid for 20, 40, 60, or 90 s. A control group for each material was evaluated without any surface treatment, totaling nine experimental groups for each material (n = 10). The specimens were evaluated for surface roughness (Ra and Rz), confocal optical microscopy, the contact angle (θ), surface free energy (γs), total free interaction energy (∆G) using a goniometer, and microshear bond strength to resin cement. Specimen images were obtained using scanning electron microscopy, confocal optical microscopy, and atomic force microscopy. Data on the surface roughness, the contact angle, surface free energy, total free interaction energy, and bond strength were subjected to two-way ANOVA and Tukey´s test (α=0.05). RESULTS: In general, Celtra Duo showed better results after etching with 10% hydrofluoric acid for 40 or 60 s. Lava Ultimate showed better performance after etching with 10% hydrofluoric acid for 20 or 40 s, whereas Vita Enamic showed better results after etching with 5% hydrofluoric acid for 90 s. CONCLUSION: Each material showed different characteristics after etching with hydrofluoric acid. Knowledge of the proper protocol for each material is essential to ensure improvements in the adhesion process and durability of indirect restorations. In general, Celtra Duo presented mechanical properties superior to those of Lava Ultimate and Vita Enamic. CLINICAL SIGNIFICANCE: Specific etching protocols must be recommended for each indirect material because longer exposure to hydrofluoric acid can jeopardize the surface, thus affecting the mechanical and bond strength properties.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Porcelana Dentária/química , Teste de Materiais , Propriedades de Superfície , Materiais Dentários/química , Cimentos de Resina/química , Cerâmica/química , Desenho Assistido por Computador
5.
J Mech Behav Biomed Mater ; 123: 104762, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34371332

RESUMO

PURPOSE: Studies evaluating different features of cold plasma action on dentin surface characteristics are lacking. Thus, this in vitro study aimed to determine the effect of cold plasma under different protocols of exposure time, distance to plasma source, and the association of argon gas with distinct concentrations of oxygen on the wettability, surface energy, total free interaction energy, surface roughness, morphology and chemical composition of dentin. MATERIAL AND METHODS: One hundred and twenty-five bovine dentin samples were used and divided into twenty-five groups according to the exposure time to plasma (15, 30, or 60 s); distance between plasma source and dentin surface (3 or 6 mm); argon gas without plasma generation; and plasma generated by argon gas and association of argon gas with distinct concentrations of oxygen (2 % or 3 %) (n = 5). Contact angle (θ), surface energy (γs) and total free interaction energy (ΔG) were measured using a goniometer (Krüss), while surface roughness (Ra) was evaluated by a profilometer (Mitutoyo). Representative samples were submitted to scanning electron microscopy (JEOL) to ilustrate the morphology and chemical composition of dentin. Data comparing control group with all experimental groups were submitted to ANOVA followed by Tukey's test (α = .05). Data comparing oxygen gas action at different concentrations and argon gas on dentin characteristics were submitted to non-parametric Kruskal-Wallis test, followed by Dunn test for comparison between the groups and methods (α = 0.05). RESULTS: In general, argon gas without plasma generation promoted no significant difference on dentin surface characteristics compared to control group (P > .05), differently for the cold plasma that significantly reduced contact angle values and increased total free interaction energy of dentin surface (P < .05). Overall, feeding of oxygen at distinct concentrations promoted significant difference on dentin surface characteristics compared to control group (P < .05). Exposure time and distance protocols interfered with contact angle, surface energy and total free interaction energy analyses for each gas. There was no significant difference on surface roughness (P > .05), morphology and chemical composition of dentin submitted to argon gas, cold plasma, and distinct concentrations of oxygen. CONCLUSION: In conclusion, plasma generated by argon gas and its feeding with 2 % and 3 % oxygen gas improved the dentin surface characteristics about wettability, surface energy and total free interaction energy. Such treatments preserved the surface roughness, morphology and chemical composition of dentin. The protocols of groups Ar-6mm-15sec, ArO2-3mm-30sec and ArO3-3mm-15sec are recommended for improvement of dentin surface characteristics.


Assuntos
Gases em Plasma , Animais , Argônio , Bovinos , Dentina , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Molhabilidade
6.
J Appl Oral Sci ; 28: e20200493, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32997089

RESUMO

OBJECTIVE: This study aimed to evaluate the effects of different toothpastes on the surface wear of enamel, dentin, composite resin (CR), and resin-modified glass ionomer cement (RMGIC), and to perform a topographic analysis of the surfaces, based on representative images generated by atomic force microscopy (AFM) after erosion-abrasion cycles. METHODOLOGY: One hundred and forty bovine incisors were collected and divided into two groups: 72 enamel and 72 dentin blocks (4×4 mm). Half of the specimens were restored with CR (Filtek Z350 XT) and the other half with RMGIC (Fuji II LC). Then, samples were submitted to a demineralization cycle (5 days, 4×2 min/day, 1% citric acid, pH 3.2) and exposed to three different toothpastes (2×15 s/day): without fluoride (WF, n=12), sodium fluoride-based (NaF, n=12), and stannous fluoride-based (SnF2, n=12). Surface wear, as well as restoration interfaces wear, were investigated by profilometry of the dental substrates and restorative materials. All representative surfaces underwent AFM analysis. Data were analyzed by two-way analysis of variance and Tukey's tests (α=0.05). RESULTS: NaF-based toothpaste caused the greater dentin surface wear (p<0.05). Toothpastes affected only enamel-restoration interfaces. AFM analysis showed precipitate formation in dentinal tubules caused by the use of fluoride toothpastes. CONCLUSIONS: NaF-based toothpastes had no protective effect on enamel adjacent to CR and RMGIC against erosion-abrasion challenges, nor on dentin adjacent to RMGIC material. SnF2-based toothpastes caused more damage to interfaces between enamel and RMGIC.


Assuntos
Resinas Compostas , Cimentos de Ionômeros de Vidro , Erosão Dentária , Cremes Dentais , Animais , Bovinos , Esmalte Dentário , Dentina , Erosão Dentária/induzido quimicamente , Erosão Dentária/prevenção & controle
7.
J. appl. oral sci ; 28: e20200493, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1134787

RESUMO

Abstract Objective This study aimed to evaluate the effects of different toothpastes on the surface wear of enamel, dentin, composite resin (CR), and resin-modified glass ionomer cement (RMGIC), and to perform a topographic analysis of the surfaces, based on representative images generated by atomic force microscopy (AFM) after erosion-abrasion cycles. Methodology One hundred and forty bovine incisors were collected and divided into two groups: 72 enamel and 72 dentin blocks (4×4 mm). Half of the specimens were restored with CR (Filtek Z350 XT) and the other half with RMGIC (Fuji II LC). Then, samples were submitted to a demineralization cycle (5 days, 4×2 min/day, 1% citric acid, pH 3.2) and exposed to three different toothpastes (2×15 s/day): without fluoride (WF, n=12), sodium fluoride-based (NaF, n=12), and stannous fluoride-based (SnF2, n=12). Surface wear, as well as restoration interfaces wear, were investigated by profilometry of the dental substrates and restorative materials. All representative surfaces underwent AFM analysis. Data were analyzed by two-way analysis of variance and Tukey's tests (α=0.05). Results NaF-based toothpaste caused the greater dentin surface wear (p<0.05). Toothpastes affected only enamel-restoration interfaces. AFM analysis showed precipitate formation in dentinal tubules caused by the use of fluoride toothpastes. Conclusions NaF-based toothpastes had no protective effect on enamel adjacent to CR and RMGIC against erosion-abrasion challenges, nor on dentin adjacent to RMGIC material. SnF2-based toothpastes caused more damage to interfaces between enamel and RMGIC.


Assuntos
Animais , Bovinos , Erosão Dentária/induzido quimicamente , Erosão Dentária/prevenção & controle , Cremes Dentais , Resinas Compostas , Cimentos de Ionômeros de Vidro , Esmalte Dentário , Dentina
8.
J Mech Behav Biomed Mater ; 97: 7-12, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31082715

RESUMO

The aim of this study was to evaluate the mechanical resistance of dentin and restorative materials submitted to erosive/abrasive challenges with different dentifrices. The dentin was restored using a resin-modified glass-ionomer (RMGIC) or a composite resin (RC). One hemiface of the sample was protected, and the other was subdivided according to the applied dentifrice (n = 10): without fluoride (SF), sodium fluoride (NaF) and stannous fluoride (SnF). The specimens were submitted to erosive/abrasive cycles, the varnish was removed, and the Martens hardness (HMV) and elastic modulus (Eit) were evaluated. The data were analyzed by repeated two-way ANOVA measurements and Tukey tests (alpha = 0.05). When analyzing the HMV on the test side, there was no influence of the dentifrices in the dentin; however, the orders of NaF < SnF = SF in RC and SnF > NaF = SF in RMGIC were observed. Comparing the treated surfaces, there were no differences in the dentin, and only the SF since CR presented an HMV superior to that of RMGIC. Comparing control and test sides, both dentins obtained a decreased HMV after the erosive/abrasive challenge; for the restorative materials, superior values were found only for SnF in the RMGIC. The Eit values were influenced more by the dentifrices on the test side for the dentin adjacent to the RMGIC, with the lowest values shown for the SF, and for both materials, the highest values were shown for the SnF group. No differences were found when comparing each dentin treated with the same dentifrice; however, the RMGIC presented a superior Eit than the CR when brushed with both dentifrices with a fluoride. Comparing the control and test sides, the same results were obtained for the HMV. The dentifrices showed little influence on the dentin substrate, whereas the dentifrice with SnF enhanced the mechanical properties of the restorative materials, which was more evident in the RMGIC.


Assuntos
Resinas Acrílicas/química , Dentifrícios/farmacologia , Dentina/química , Dentina/efeitos dos fármacos , Dióxido de Silício/química , Fluoreto de Sódio/farmacologia , Fluoretos de Estanho/farmacologia , Animais , Bovinos , Resinas Compostas/química , Módulo de Elasticidade , Dureza , Técnicas In Vitro , Teste de Materiais , Pressão , Estresse Mecânico , Propriedades de Superfície
9.
Braz Dent J ; 30(2): 106-116, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30970052

RESUMO

The aim of this study was to evaluate the push-out bond strength and interface permeability of glass-fiber posts in different regions of post space (cervical, middle, and apical) submitted to different irrigation solutions. Ninety single-rooted human teeth were submitted to endodontic treatment and divided into five groups, according to irrigation solutions: distilled water, 5.25% NaOCl, 25% polyacrylic acid, 2% chlorhexidine, and 23 ppm Ag NP dispersion. Each group was divided in 3 subgroups (n=6) according to cementation: SBU: Adper Scotchbond Universal + RelyX ARC; U200: RelyX U200; MCE: MaxCem Elite. Bond strength and sealing ability were measured in different areas of post space. The data was subjected to ANOVA and Fisher's test (a=0,05). The silver nanoparticle solution showed highest bond strength values and lowest interface permeability in all thirds analyzed for SBU group. In the U200 group, the highest bond strength values were found for sodium hypochlorite solution, with significant difference between this solution and polyacrylic acid. A decrease in bond strength values in cervical to apical direction was found for MCE group and the same behavior were found for others groups. Regarding interface permeability, use of silver nanoparticle solution resulted in lower values in cervical and apical thirds. There was a decrease in bond strength in cervical to apical direction. Different irrigation solutions and intraradicular depth influenced the bond strength and interface permeability of adhesive material to dentin substrate. Silver nanoparticle solution can effectively be used as an irrigation agent in post space prior to fiber post cementation process.


Assuntos
Colagem Dentária , Nanopartículas Metálicas , Técnica para Retentor Intrarradicular , Dentina , Vidro , Humanos , Teste de Materiais , Cimentos de Resina , Prata
10.
Braz Oral Res ; 33: e024, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30970089

RESUMO

The aim of this study is to evaluate the effect of chitosan or nanodiamond incorporation on the color stability and surface roughness of a bisacrylic resin subjected to artificial aging. Four bisacrylic resins were evaluated, namely, control, chitosan-modified material, nanodiamond-modified material, and chitosan-nanodiamond-modified material. Twenty-four specimens were prepared for each material. The surface roughness was determined using a profilometer with a cut-off of 0.25 mm. The baseline color was measured according to the CIE L*a*b* system using a reflectance spectrophotometer. After these tests, the specimens were individually immersed in cola soft drink, red wine, or distilled water (n = 8) for 28 days. After the aging, the surface roughness and final color were re-evaluated. The color stability was determined using the difference between the coordinates obtained before and after the aging process. The data on roughness and color change were evaluated using ANOVA and the Tukey test (α = 0.05). The results show that the incorporation of nanodiamonds and chitosan into a bisacrylic resin provided a better color stability to the materials (p = 0.007). The storage in red wine resulted in a higher variation in the surface roughness values, especially when only the nanodiamond was incorporated to the material (p < 0.05). The incorporation of both chitosan and nanodiamonds are promising in providing an improvement in the properties of the bisacrylic resin when they are simultaneously incorporated in the product.


Assuntos
Resinas Acrílicas/química , Quitosana/química , Cor , Resinas Compostas/química , Nanodiamantes/química , Análise de Variância , Bebidas Gaseificadas , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Espectrofotometria , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo , Água/química , Vinho
11.
Braz. dent. sci ; 22(3): 371-377, 2019. tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1009280

RESUMO

Objective: the aim of this study is to evaluate the microhardness and color change (∆E) of composite resins, that were light-cured with different LEDs, after being immersed in a staining drink. Material and Methods: Two composite resins with Lucerin-TPO (Tetric N-Ceram/ Vit-l-escence) and camphorquinone (Filtek Z350) were selected. The specimens (n=120) were prepared and lightcured with LED of monowave or polywave lightemitting diode (LED) devices. Microhardness and color evaluations were measured before and after immersion in staining drink. Microhardness data were evaluated by Kruskal-Wallis test, MannWhitney and Wilcoxon tests. Color changes were evaluated by two-way analysis of variance (ANOVA) and Tukey test (p ≤ 0.05). Results: No statistically significant difference between the two generations of LEDs was found for microhardness data. Regarding the ∆E, a statistical difference between the two LEDs was observed for Tetric NCeram and Filtek Z350. Conclusion: The compostion of composites appears to have more influence on analyses than the type of LEDs used. A decreased microhardness occurred to Vit-lescence for monowave and to Filtek Z350 for both LED devices. A clinically perceptible color change was observed for Tetric-N Ceram and Filtek Z350 when polywave LED were used. (AU)


Objetivo: o objetivo deste estudo foi aviliar a microdureza e alteração de cor (∆E) de resinas compostas, fotoativadas com diferentes LEDs, imergidas em bebidas pigmetadas. Material e métodos: Duas resinas compostas com Lucerina-TPO (Tetric N-Ceram/ VIt-l-essence) e canforoquinona (Filtek Z350) foram selecionadas. Os espécimes (n=120) foram preparados. Os mesmos foram fotopolimerizados com LED monowave ou polywave. Microdureza e cor foram avaliadas antes e após a imersão em bebidas pigmentadas. Os dados de microdureza foram avaliados pelos testes de Kruskal-Wallis, Mann-Whitney e Wilcoxon. As alterações de cor foram avaliadas por análise de variância a dois critérios (ANOVA) e Tukey (p ≤ 0,05). Resultados: Não foi encontrada diferença estatística entre as duas gerações de LEDs, para os dados da microdureza. Quanto ao ∆E, foi encontrada diferença estatisticamente significante entre os dois LEDs, sendo observadas na Tetric N-Ceram na FIltek Z350. Conclusão: A composição das resinas compostas parece ter mais influencia nas análises do que o tipo de LEDs. Uma redução na microdureza ocorreu para Vit-lescence para monowave e para Filtek Z350 para ambos os dispositivos LED. Uma mudança de cor clinicamente perceptível foi observada em Tetric-N Ceram para polywave e Filtek Z350 para ambos os dispositivos LED. (AU)


Assuntos
Resinas Compostas , Luzes de Cura Dentária , Fotoiniciadores Dentários , Polimerização
12.
Braz. j. oral sci ; 18: e191451, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1087501

RESUMO

Aim The aim of this study is to evaluate the degree of conversion (DC) of resin cements polymerized under different thicknesses of feldspathic dental ceramic. Methods: Forty samples of RelyX ARC and RelyX Veneer resin cements were polymerized under Starlight feldspathic ceramic discs (DeguDent Gmbh) with 0.5 mm, 1.2 mm, 1.8 mm, and 2.4 mm in thickness. The control group was cured without the interposition of ceramic. The DC measurements were performed 10 minutes, 1 hour, and 24 hours after the light-activation in a Nexus 670 FTIR spectrophotometer. Data were analyzed by two-way repeated measure ANOVA and Fisher PLSD test. Results: The RelyX ARC showed higher DC for all ceramic thicknesses. There was significant decrease in DC related to an increase in ceramic thickness. For RelyX ARC, the values of DC obtained after 1 hour and 24 hours did not differ statistically between them, but they were higher than those analyzed after 10 minutes. For RelyX Veneer cement, there was gradual increase in the DC up to 24 hours. Conclusion: The higher the thicknesses of ceramic, the lower DC of the resin cement


Assuntos
Cerâmica , Cimentos de Resina , Polimerização
13.
Eur J Dent ; 12(4): 559-565, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30369803

RESUMO

OBJECTIVE: This study aims to evaluate the effect of acidic solutions (AS) on surface roughness (Ra) and microhardness of restorative materials (RM). MATERIALS AND METHODS: Eight volunteers wore intraoral palatal devices (IPD) containing samples of RM: Ketac Nano (KN); Ketac Nano + Biscover LV (KN-B); Esthet-X (EX); Esthet-X + Biscover LV (EX-B); Supreme XT (SXT); Supreme XT + Biscover LV (SXT-B); and bovine enamel. The samples were submitted to three phases: (1) immersion in 0.01M hydrochloric acid (HCl) - 10 min, three times/day (14 days); (2) immersion in soft drink (Sprite®) - 10 min, three times/day (14 days); and (3) keeping in saliva (14 days). Changes in Ra/microhardness were measured before/after the three phases. STATISTICAL ANALYSIS: ANOVA (α = 0.05) and Fisher's test. RESULTS: Materials sealed with Biscover LV (B) presented lowest values in all periods. KN glass ionomer cement showed highest Ra values after exposure in AS. Application of B did not reduce the Ra for the composites studied, except for EX after immersion in HCl. AS promoted changes in Ra/microhardness of RM, except for sealed materials. CONCLUSIONS: The acids used were able to change the Ra and microhardness of RM, except of the sealed materials. The resin-modified GIC showed the most significant changes after immersion in AS; and the composites sealed with B, even after immersion in acidic solutions (AS), showed the lowest Ra values and the least degradation in microhardness, especially when subjected to low pH solutions.

14.
Eur J Dent ; 12(3): 446-449, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30147415

RESUMO

This case report presents a minimally invasive diastema treatment using cordless gingival displacement system allowing a very conservative intervention. A 32-year-old female patient who presented with diastema in her upper front teeth opted for a treatment using laminate veneers to ensure achieving adequate tooth proportion and gingival levels. Having a displacement material that exerts excessive pressure during the displacement process can lead to disruption of the junctional epithelium and damage to periodontal tissues. This case report focuses on the effectiveness of the use of a minimally invasive method of gingival management. Two-year follow-up no infiltration, sensitivities, or fractures were detected on teeth, and indirect restorations, the purposed treatment allowed a quick, effective, and durable resolution for diastema.

15.
J Appl Oral Sci ; 26: e20170284, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29742258

RESUMO

Objective The objective of this study was to evaluate dental sensitivity using visual analogue scale, a Computerized Visual Analogue Scale (CoVAS) and a neurosensory analyzer (TSA II) during at-home bleaching with 10% carbamide peroxide, with and without potassium oxalate. Materials and Methods Power Bleaching 10% containing potassium oxalate was used on one maxillary hemi-arch of the 25 volunteers, and Opalescence 10% was used on the opposite hemi-arch. Bleaching agents were used daily for 3 weeks. Analysis was performed before treatment, 24 hours later, 7, 14, and 21 days after the start of the treatment, and 7 days after its conclusion. The spontaneous tooth sensitivity was evaluated using the visual analogue scale and the sensitivity caused by a continuous 0°C stimulus was analyzed using CoVAS. The cold sensation threshold was also analyzed using the TSA II. The temperatures obtained were statistically analyzed using ANOVA and Tukey's test (α=5%). Results The data obtained with the other methods were also analyzed. 24 hours, 7 and 14 days before the beginning of the treatment, over 20% of the teeth presented spontaneous sensitivity, the normal condition was restored after the end of the treatment. Regarding the cold sensation temperatures, both products sensitized the teeth (p<0.05) and no differences were detected between the products in each period (p>0.05). In addition, when they were compared using CoVAS, Power Bleaching caused the highest levels of sensitivity in all study periods, with the exception of the 14th day of treatment. Conclusion We concluded that the bleaching treatment sensitized the teeth and the product with potassium oxalate was not able to modulate tooth sensitivity.


Assuntos
Sensibilidade da Dentina/induzido quimicamente , Sensibilidade da Dentina/diagnóstico , Medição da Dor/métodos , Peróxidos/efeitos adversos , Clareadores Dentários/efeitos adversos , Clareamento Dental/efeitos adversos , Ureia/análogos & derivados , Adolescente , Adulto , Análise de Variância , Peróxido de Carbamida , Feminino , Humanos , Masculino , Ácido Orótico/uso terapêutico , Limiar da Dor , Peróxidos/química , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ureia/efeitos adversos , Ureia/química , Escala Visual Analógica , Adulto Jovem
16.
J Appl Oral Sci ; 26: e20170043, 2018 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-29364338

RESUMO

This study verified the occurrence of dental sensitivity in patients submitted to a 35% hydrogen peroxide based product (Whiteness HP Maxx 35% - FGM), skin cold sensation threshold (SCST) and its influence on dental sensitivity. Sixty volunteers were divided into 4 groups (n = 15), according to SCST (low: GI and GIII, and high: GII and IV) and bleaching treatment (hydrogen peroxide: GI and GII, and placebo: GIII and GIV). SCST was determined in the inner forearm for 6 different times using a neurosensory analyzer, the TSA II (Medoc Advanced Medical Systems, Ramat Yishai, Northern District, Israel). Dental sensitivity measurements were performed 10 different times using a thermal stimulus and an intraoral device attached to TSA II, positioned in the buccal surface of the upper right central incisor. Spontaneous dental sensitivity was also determined using the Visual Analogue Scale (VAS). Data were submitted to Student's t-test and Pearson's Correlation Test (α=0.05). SCST remained the same during bleaching treatment. Distinct responses of dental sensitivity were found in patients with low and high SCST during the first and third bleaching session (p≤0.05). The teeth submitted to the bleaching treatment became more sensitive to cold than those treated with placebo. Moreover, data obtained with TSA and VAS presented moderate correlation. Bleaching treatment increased dental sensitivity and skin cold sensation threshold might represent a determining factor in this occurrence, since low and high SCST patients had different responses to the thermal stimulus in the teeth.


Assuntos
Sensibilidade da Dentina/induzido quimicamente , Peróxido de Hidrogênio/efeitos adversos , Temperatura Cutânea/efeitos dos fármacos , Clareadores Dentários/efeitos adversos , Clareamento Dental/efeitos adversos , Adolescente , Adulto , Temperatura Baixa , Humanos , Masculino , Medição da Dor , Efeito Placebo , Valores de Referência , Limiar Sensorial , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
17.
Braz. j. oral sci ; 17: e18127, 2018. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-963817

RESUMO

Aim: The aim of this study was to verify the microshear bond strength of conventional and self-adhesive resin cements to feldsphatic ceramic. Methods: Twenty discs of Starlight ceramic (Degudent) were made (15mm x 2mm). The bonding procedure was accomplished by insertion of resin cements into tubes of 0.7mm internal diameter in contact with the ceramic. The resin cements used were: RelyX ARC (3M Espe), Panavia F (Kuraray), RelyX Unicem (3M Espe) and seT (SDI). Total of six tubes of each material on each ceramic disc. The specimens were tested for microshear in a universal testing machine, 24hours and 6months after bonding procedure. Values of microshear bonding strength (MPa) were subjected to ANOVA and Fisher PLSD test (p<0.05). Results: For 24hours analysis, RelyX ARC showed the highest microshear bonding strength without statistical difference to RelyX Unicem and seT. Panavia F showed the lowest values of microshear bonding strength in both periods. In the analysis after 6months there was a significant increase in the microshear bonding strength values for all cements compared to 24hours. Only for RelyX ARC, the increase was not statistically significant. Conclusion: In conclusion, the bond strength depends mainly on the type of resin cement used, and the self-adhesive cements behave similarly to conventional resin cement


Assuntos
Cerâmica , Adesivos Dentinários , Cimentos de Resina , Resistência ao Cisalhamento
18.
J. appl. oral sci ; 26: e20170043, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893713

RESUMO

Abstract Objective This study verified the occurrence of dental sensitivity in patients submitted to a 35% hydrogen peroxide based product (Whiteness HP Maxx 35% - FGM), skin cold sensation threshold (SCST) and its influence on dental sensitivity. Material and Methods Sixty volunteers were divided into 4 groups (n = 15), according to SCST (low: GI and GIII, and high: GII and IV) and bleaching treatment (hydrogen peroxide: GI and GII, and placebo: GIII and GIV). SCST was determined in the inner forearm for 6 different times using a neurosensory analyzer, the TSA II (Medoc Advanced Medical Systems, Ramat Yishai, Northern District, Israel). Dental sensitivity measurements were performed 10 different times using a thermal stimulus and an intraoral device attached to TSA II, positioned in the buccal surface of the upper right central incisor. Spontaneous dental sensitivity was also determined using the Visual Analogue Scale (VAS). Data were submitted to Student's t-test and Pearson's Correlation Test (α=0.05). SCST remained the same during bleaching treatment. Results Distinct responses of dental sensitivity were found in patients with low and high SCST during the first and third bleaching session (p≤0.05). The teeth submitted to the bleaching treatment became more sensitive to cold than those treated with placebo. Moreover, data obtained with TSA and VAS presented moderate correlation. Conclusions Bleaching treatment increased dental sensitivity and skin cold sensation threshold might represent a determining factor in this occurrence, since low and high SCST patients had different responses to the thermal stimulus in the teeth.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Adulto Jovem , Temperatura Cutânea/efeitos dos fármacos , Clareamento Dental/efeitos adversos , Sensibilidade da Dentina/induzido quimicamente , Clareadores Dentários/efeitos adversos , Peróxido de Hidrogênio/efeitos adversos , Valores de Referência , Limiar Sensorial , Fatores de Tempo , Medição da Dor , Efeito Placebo , Resultado do Tratamento , Temperatura Baixa
19.
J. appl. oral sci ; 26: e20170284, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893698

RESUMO

Abstract Objective The objective of this study was to evaluate dental sensitivity using visual analogue scale, a Computerized Visual Analogue Scale (CoVAS) and a neurosensory analyzer (TSA II) during at-home bleaching with 10% carbamide peroxide, with and without potassium oxalate. Materials and Methods Power Bleaching 10% containing potassium oxalate was used on one maxillary hemi-arch of the 25 volunteers, and Opalescence 10% was used on the opposite hemi-arch. Bleaching agents were used daily for 3 weeks. Analysis was performed before treatment, 24 hours later, 7, 14, and 21 days after the start of the treatment, and 7 days after its conclusion. The spontaneous tooth sensitivity was evaluated using the visual analogue scale and the sensitivity caused by a continuous 0°C stimulus was analyzed using CoVAS. The cold sensation threshold was also analyzed using the TSA II. The temperatures obtained were statistically analyzed using ANOVA and Tukey's test (α=5%). Results The data obtained with the other methods were also analyzed. 24 hours, 7 and 14 days before the beginning of the treatment, over 20% of the teeth presented spontaneous sensitivity, the normal condition was restored after the end of the treatment. Regarding the cold sensation temperatures, both products sensitized the teeth (p<0.05) and no differences were detected between the products in each period (p>0.05). In addition, when they were compared using CoVAS, Power Bleaching caused the highest levels of sensitivity in all study periods, with the exception of the 14th day of treatment. Conclusion We concluded that the bleaching treatment sensitized the teeth and the product with potassium oxalate was not able to modulate tooth sensitivity.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Peróxidos/efeitos adversos , Clareamento Dental/efeitos adversos , Ureia/análogos & derivados , Medição da Dor/métodos , Sensibilidade da Dentina/diagnóstico , Sensibilidade da Dentina/induzido quimicamente , Clareadores Dentários/efeitos adversos , Ácido Orótico/uso terapêutico , Peróxidos/química , Fatores de Tempo , Ureia/efeitos adversos , Ureia/química , Índice de Gravidade de Doença , Análise de Variância , Resultado do Tratamento , Limiar da Dor , Escala Visual Analógica , Peróxido de Carbamida
20.
Braz Dent J ; 27(4): 399-403, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27652700

RESUMO

Abastract This study aimed to evaluate the transenamel and transdentinal penetration of hydrogen peroxide (H202) applied to bovine teeth pigmented with black tea at different intensities. The following groups were formed DW: immersion in distilled water; BT100: immersion in an infusion of 1.6 g of black tea per 100 mL distilled water; BT10: immersion in an infusion of 1.6 g black tea per 10 mL distilled water. All groups were immersed for 6 days. To quantify the penetration of H202, the specimens were placed in artificial pulp chambers (APCs) and subjected to bleaching treatment with 38% H2O2 once per week for 3 weeks. After bleaching treatment, the acetate buffer solution of APCs with peroxidase enzyme was evaluated in a reflection spectrophotometer. The transenamel and transdentinal penetration of H2O2 and the L* values obtained at T1, T2 and T3 were subjected to Kruskal-Wallis and Friedman statistical tests. At T1, the H2O2 diffusion in DW was higher than that in BT100 and BT10. At the other evaluation times, the penetration values in BT100 and BT10 increased and remained similar. The L* values increased significantly in all groups at T1. At T2, the L* values were higher in DW, while the values in BT100 and BT10 were similar to each other. At the end of the experiment, BT10 showed the lowest L* values. The pigmentation level did not affect the penetration of H2O2 through the enamel and dentin and the bleaching agent effectively changed the color of the teeth.


Assuntos
Dentina/metabolismo , Peróxido de Hidrogênio/farmacocinética , Pigmentação , Dente , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...